EXTENDING THE LIFE OF A TRAVELING WAVE TUBE
The Traveling Wave Tube (TWT) is the heart of your TWT amplifier
(TWTA), as well as its most expensive component. And while MCL
prides itself on providing state-of-the-art amplifiers designed to
extend tube life in a variety of ways, the owner/operator of a TWTA
should be aware of the following list of suggested precautions that
will help maximize their TWT investment by contributing to the
tube's performance and life.
Handling of Replacement TWTs
When you take delivery of a new TWT, careful handling during
installation is advisable. Special attention should be given to
ensure that the exposed high-voltage connections, ceramic seals and
RF connectors are protected from damage which may occur during the
process of unpacking the TWT.
Installation
Only trained personnel should participate in the removal or
installation of a TWT. This person must proceed with caution so that
no strain is put on the RF connectors. On TWTs with SMA connectors,
precautions should be exercised as to the amount of torque applied
to the connectors - 8 inch-pounds is the recommended torque. The
waveguide mating flanges should be clean, smooth and flat so that a
good mechanical, as well as RF connection can be made. Any o-rings
must be clean and aligned in the groove to avoid pinching. Ensure
proper connections are made pertaining to the individual elements of
the TWT.
Storage
If at all possible, the original shipping container should be
retained and used for storing the TWT and for any future handling or
moving which may be required. In addition, the specific storage
temperature limits must not be exceeded. Specific storage
temperatures can be found with the tube data in your documentation.
Protective Measures
Steps must be taken to provide protective measures so that the
TWT is not exposed to abnormal extremes, such as AC line surges,
temperatures, and load mismatches. All MCL TWTAs are supplied with
operating instructions and test performance data. Owners/operators
should take the time to read and refer to these manuals on a regular
basis. Special attention should be given to the recommended
precautions and operating instructions.
Preventative Maintenance
Develop a regular maintenance plan for the inspection and
cleaning of air filters. Air filters should be maintained at least
once a month. If the filters are found to be very dirty, the
frequency of the maintenance period should be increased. The
frequency may also need to be increased during dry periods or when
there is construction nearby. In highly corrosive environments (i.e.
salt air) the filter should be replaced at regular intervals.
Proper Cooling
A key factor in extending the life of any TWT is controlling the
temperature of the tube at all times. Most systems produced by MCL
are designed with cooling systems to ensure reliability and long
life at temperatures up to 50 deg C at sea level and derated at 1.9
deg C per 1000 ft. at altitudes up to 10,000 ft. Do not operate
systems for extended periods of time or at high ambient temperature
conditions with the HPA covers off or doors open. In many cases
these doors are an integral part of the cooling design. Air will not
flow correctly and some items will not be cooled adequately. Air
filtering will also be compromised.
TWT Operation
By adhering to the following general operational principles, TWT
life can be extended:
Longest Life (Steady State) - Beam and RF on continuously
(Unit in Transmit position)
Beam on, RF off during downtime (Unit in Transmit position)
HPA (Beam and Heater/Filament) off during long downtime (Unit
Off)
Shorter Life (Transients) - Heater/Filament Voltage full
on, Beam off (Unit in Standby position)
Protection During Faults
Although all MCL amplifiers are designed to provide maximum
operational efficiency, it is possible that during the life of your
amplifier a fault may occur. If a fault does occur, resetting the
fault is a normal procedure. Should the fault fail to clear after
three attempts, MCL recommends that you log all operational
parameters (i.e. meters and voltages) and contact us immediately. If
further attempts to reset the fault are made to the system, damage
to the TWT may result.
In general, all major tube manufacturers agree that a cooler
running cathode (TWT) provides the best long life performance. By
following the suggestions in this article, you can get the maximum
return on your HPA investment by significantly extending the life of
the TWT.
For more information, please
contact us.
Back